Categories
Knowledge Base
Contact Us

360 Goddard
Irvine, CA 92618
U.S.A.
Tel: 1-949-609-9636
Fax: 1-949-812-6690
E-mail: sales@valves-fittings.com

Live Chat Help
You are here: Home » Products » Sanitary Check Valves » Details
Product
Sanitary Check Valve

Sanitary Check Valve

Applications
CV4 sanitary check valve is used in stainless steel pipe systems to prevent backward flow of fluids.

Operating Principle
When the pressure of lower valve stem exceeds that of upper valve stem and spring force, CV4 sanitary check valve is open. When the pressure of upper valve stem equals that of lower valve stem, CV4 sanitary check valve is closed. Greater reverse pressure acting on the valve stem causes the valve to close.

CV4 sanitary check valve has two configurations.

CV4-1 sanitary check valve adopts clamp connection method. It is affordable and widely used in food industry.

CV4-2 sanitary check valve consists of a thickened valve body and two flanges, which is easy to install and remove.

Correct Installation Method

Sanitary Check Valve Correct Installation Method

Pressure Drop/Capacity Comparison Diagram

Sanitary Check Valve Pressure Drop/Capacity Comparison Diagram

Technical Data

Metal material Product wetted 304L/316L (DIN-1.4307/1.4404) forged
Non-product wetted 304 (DIN-1.4301)
We can provide EN 10204 3.1B certificate.
Seal material Standard EPDM
Options NBR, FPM, Silicone
All seal materials comply with FDA 177.2600.
Temperature Continuous working temperature -20°C ~ +135°C (EPDM)
Sterilization temperature 150°C (Max 20min)
Pressure Opening pressure 0.08bar
Max working pressure 10bar
Surface treatment Internal surface Ra≤0.8µm
External surface Ra≤1.6µm
Connection Connection standards Welding end: DIN 11850 series 2
Welding end: Inch pipe diameter standard
Connection methods: welding, thread, clamp, flange

 

CV4-1 Sanitary Check Valve

Clamp end-male threaded end

Clamp end-male threaded end drawing

Dimensions (mm)

3A  
Size A B C D
1.0"
1.5"
22.1
34.8
37.13 ACME 8TPI
50.65 ACME 8TPI
46
46
67
67
2.0"
2.5"
47.5
60.2
64.16 ACME 8TPI
77.67 ACME 8TPI
47
50
68
71
3.0"
4.0"
72.9
97.38
91.19 ACME 8TPI
119.25 ACME 6TPI
51
60
72
72
DIN  
DN25
DN32
26
32
Rd52×1/6"
Rd58×1/6"
60
60
81
81
DN40
DN50
38
50
Rd65×1/6"
Rd78×1/6"
60
61
81
82
DN65
DN80
66
81
Rd95×1/6"
Rd110×1/4"
63
63
84
84
DN100 100 Rd130×1/4" 68 89
SMS  
25
38
22.5
35.5
RD40×1/6"
RD60×1/6"
53
58
74
79
51
63.5
48.5
60.5
RD70×1/6"
RD85×1/6"
58
62
79
83
76
101.6 Min
72.9
97.6
RD98×1/6"
RD125×1/4"
66
72
83
83
101.6 Max 97.6 RD132×1/6" 72 83

Clamp end-welding end

Clamp end-welding end drawing

Dimensions (mm)

Inch  
Size A B C D
1/2"
3/4"
9.4
15.75
12.7
19.05
28.5
28.5
39.5
39.5
1.0"
1.5"
22.1
34.8
25.4
38.1
38
38
59
59
2.0"
2.5"
47.5
60.2
50.8
63.5
38
38
59
59
3.0"
4.0"
72.9
97.38
76.2
101.6
42
44
59
55
DIN  
DN20
DN25
20
26
23
29
28.5
38
39.5
59
DN32
DN40
32
38
35
41
38
38
59
59
DN50
DN65
50
66
53
70
38
38
59
59
DN80
DN100
81
100
85
104
42
44
59
55

Clamp end-clamp end

Clamp end-clamp end drawing

Dimensions (mm)

3A / SMS / ISO  
Size A B C D
1/2"
3/4"
9.4
15.75
25.2
25.2
28.5
28.5
39.5
39.5
1.0"
1.5"
22.1
34.8
50.5
50.5
38
38
59
59
2.0"
2.5"
47.5
60.2
64
77.5
38
38
59
59
3.0"
4.0"
72.9
97.38
91
119
42
44
59
55
DIN  
DN20
DN25
20
26
34
50.5
28.5
38
39.5
59
DN32
DN40
32
38
50.5
50.5
38
38
59
59
DN50
DN65
50
66
64
91
38
38
59
59
DN80
DN100
81
100
106
119
42
44
59
55

CV4-2 Sanitary Check Valve

ZH4-2 Sanitary Check Valve Drawing

Dimensions (mm)

Inch  
Size A B C H
1.0"
1.5"
22.1
34.8
25.4
38.1
87
97
90
90
2.0"
2.5"
47.5
60.2
50.8
63.5
110
127
110
120
3.0"
4.0"
72.9
97.38
76.2
101.6
142
162
145
150
DIN  
DN25
DN32
26
32
29
35
87
92
90
90
DN40
DN50
38
50
41
53
97
110
90
110
DN65
DN80
66
81
70
85
127
142
120
145
DN100 100 104 162 150